Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 Mar 2021
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: JIS K2265 Determination of flash point-Part 4: Cleveland open cup method
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland Open Cup
Flash point:
336 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: average of four measurements

Description of key information

Flash point: 336 °C at ca. 1013 hPa (JIS K2265, Cleveland open cup method)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
336 °C

Additional information

The flash point of the test substance was determined by Cleveland open cup method according JIS K2265. Since the measured flash point is far above the classification limit and above 200 °C, the open-cup method is accepted and the result is taken as reliable with restrictions.