Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 Jan 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Principles of method if other than guideline:
1. The explosive properties were determined using a Koenen apparatus.
2. Predicted using Method A.14 (based on the structure).
GLP compliance:
no
Test series:
UN Test series 2
Method:
UN Test 2 (b): Koenen test
Parameter:
limiting diameter (mm)
Result:
result is considered "-" (negative)
Remarks on result:
other: limiting diameter <1 mm
Test series:
UN Test series 3
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
limiting impact energy (J)
Result:
result is considered "-" (negative)
Remarks on result:
other: limiting impact energy >50 J

THERMAL TEST

Diameter of orifice plate (mm)

Time (seconds)

Observations (explosion type)

20.0 Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

  Test 3

300

No ignition, explosion (Type O)

12.0 Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

        Test 3

300

No ignition, explosion (Type O)

8.0   Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

        Test 3

300

No ignition, explosion (Type O)

5.0   Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

        Test 3

300

No ignition, explosion (Type O)

3.0   Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

        Test 3

300

No ignition, explosion (Type O)

2.0   Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

        Test 3

300

No ignition, explosion (Type O)

1.5   Test 1

300

No ignition, explosion (Type O)

        Test 1

300

No ignition, explosion (Type O)

        Test 1

300

No ignition, explosion (Type O)

1.0   Test 1

300

No ignition, explosion (Type O)

        Test 2

300

No ignition, explosion (Type O)

        Test 3

300

No ignition, explosion (Type O)

MECHANICAL SENSITIVITY (SHOCK) TEST

Hight (m)

1

2

3

4

5

6

0.35

N

N

N

N

N

N

0.4

N

N

N

N

N

N

0.5

N

N

N

N

N

N

N= no evidence of ignition, explosion or decomposition

Description of key information

not explosive

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Based on the chemical structure and BAM test of the test material the result for explosive properties has been negative.

Justification for classification or non-classification

The available data on explosive properties of the test substance do not meet the criteria for classification according to Regulation (EC) 1272/2008 or Directive 67/548/EEC and are therefore conclusive but not sufficient for classification: Based on chemical structure the substance is not explosive.